LogTag HAXO-8 Humidity & Temperature Recorder



The LogTag Humidity & Temperature Recorder measures and stores up to 8000 sets of high resolution humidity and temperature readings over 0 to 100%RH & -40°C to +85°C (-40°F to +185°F) measurement ranges.

Using the LogTag Interface and LogTag’s freely available companion software LogTag Analyser , the LogTag is easily set-up for recording conditions including delayed start, sampling interval, number of readings, continuous or fixed number of readings and configuration of conditions to activate the ALERT indicator. Readings are downloaded using LogTag Analyser which provides facilities for charting, zooming, listing data statistics and allows exporting the data to other applications such as Excel.


Highlights 

  • Alert indicator – indicates if readings are outside of preset limits
  • OK indicator indicates if still recording and if readings within configured limits
  • Inspection mark in log by push button
  • Push Button Logging start with optional delayed start or specific Time & Date start
  • Rapid Download! Takes only seconds to download recordings
  • ‘Pre-Start’ logging - Logtag can be configured to record even if it has not been started.
  • High performance at low cost
  • Credit card sized case – thin enough to be easily mailed “letter rate”.
  • Real time clock records time & temperature simultaneously
  • Easy to use LogTag Analyser software that runs on any PC configures LogTag for recording then downloads resulting data for analysis. Data can also be exported to fomats compatible with other applications such as Excel
  • Re-calibration to achieve higher accuracy possible
  • Replaceable sensor air filter

 >> PDF Product Datasheet


Model   HAXO-8
Humdity Measurement Range   0 ~ 100%RH but with limitations as detailed in Humidity Measurement Operating and Storage conditions below
Temperature Measurement Range   -40°C to +85°C  (-40°F to +185°F)
Resolution   0.1%RH & 0.1°C/°F
Rated Accuracy  
Humidity and temperature normal and maximum operating and storage conditions   This chart shows the normal recommended operating range of the humidity sensor.
Conditions outside the normal recommended range may temporarily offset the RH signal up to ±3 %RH. After return to normal conditions it will slowly return towards calibration state by itself. Applying a “Reconditioning Procedure” may accelerate this process.
Prolonged exposure to extreme conditions may accelerate ageing.
Capacity   8032 readings (16K bytes memory)
Sampling frequency   adjustable, 30 sec to several hours
Logging start options   Push button start or specific date & time.
Recording indication   Flashing ’OK’ indicator flashing ’Alert’ indicator.
Download Time   Typically with full memory (8000 readings) in less than 5 secs depending on computer or readout device used.
Environmental   IP61
Power source   3V Lithium battery
Battery life   2 - 3 years of normal use (based on 15 minute logging, download data monthly.
Size   86mm(H) x 54.5mm(W) x 8.6mm(T)
Weight   35g
Case Material   Polycarbonate
Other features   • Logging start by push button or specific date/time start
• Optional clearing of alert indication by push button (places inspection make at same time).
• Download inspection mark recorded in LogTag memory every time LogTag is downloaded.
• ’Prestart’ fail-safe logging (records temperature data even if not started)
• Low Battery indication in software.
• Comprehensive Alert indicator configuration.
• Calibration to achieve higher accuracy possible.

Note:  Resolution & Accuracy are rated values - actual product performance may be substantially better than figures stated.

 


EMC Compliance   Tested and complies with EC EMC directives
(EN 50081-1:1992 & EN 61000-6-1:2001)
see LogTag CE mark EMC declaration of conformance
Tested and complies FCC Part 15 Subparts A and B.
see
LogTag FCC EMC declaration of conformance
FDA CFR21 Part 11 Compliance
  Designed for FDA CFR21 Part 11 Digital signatures
  Manufactured to meet the European RoHS Directive
The RoHS Directive stands for "the restriction of the use of certain hazardous substances in electrical and electronic equipment". This Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants.

 


 

 

 


 

 

 


 

 

 


 



หน้าแรก | บริษัท | สินค้าตามการใช้งาน | Sitemap/ คู่มือ /FAQ/  | ติดต่อ / สมัครงาน  
  Web hosting | website builder |เว็บไซต์สำเร็จรูป by ninenic ©Copyright 2002-2018 All rights reserved.
บริษัท ดิคเซลล์ (เอเซีย) จำกัด
2893, 2895 ถนนพัฒนาการ (ซอยพัฒนาการ 53/1 เยื้อง เขตสวนหลวง) เขตสวนหลวง กรุงเทพฯ 10250
Tel : 02 722 0245-9 Fax: 0 2320 2520
Email : dixell@dixellasia.com